Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 69
Filter
1.
Chinese Journal of Postgraduates of Medicine ; (36): 349-351, 2015.
Article in Chinese | WPRIM | ID: wpr-467743

ABSTRACT

Objective To evaluate the clinical effect of emergency pelvic external fixation in hemodynamically unstable patients with pelvic fracture.Methods The clinical data of 56 hemodynamically unstable patients with pelvic fracture from January 2008 to December 2013 were selected.The changes of hemoglobin,mean arterial pressure,heart rate,serum lactate,urine volume,norepinephrine dosage before and after surgery for 24 h were compared and analyzed.Results Compared with those before surgery,the levels of hemoglobin,mean arterial pressure,serum lactate,urine volume,heart rate after surgery for 24 h were significantly improved:(109 ± 12) g/L vs.(69 ±22) g/L,(87.8 ±6.5) mmHg (1 mmHg =0.133 kPa) vs.(55.8 ± 7.7) mmHg,(6.3 ± 5.1) mmol/L vs.(10.8 ± 6.6) mmol/L,(35.9 ± 9.9) ml/h vs.(17.6 ± 8.4) ml/h,(84.2 ± 15.4) times/min vs.(146.4 ± 12.1) times/min,and the norepinephrine dosage was significantly reduced:(0.8 ± 0.2) μ g/ (kg· min) vs.(2.2 ± 0.8) μ g/ (kg· min).The differences had statistical significance (P < 0.05 or < 0.01).Conclusion Bedside pelvic external fixation can rapidly improve shock symptom in hemodynamically unstable patients with pelvic fracture,which is safe and efficient.

2.
Chinese Journal of cardiovascular Rehabilitation Medicine ; (6): 581-583, 2014.
Article in Chinese | WPRIM | ID: wpr-473738

ABSTRACT

Transpulmonary thermodilution pulse-indicated continuous cardiac output (PiCCO) monitoring only needs a central venous catheter and an artery catheter ,so is a minimally invasive ,simple ,accurate and continuous cardiac output monitor technique used at home and abroad now .It combines transpulmonary thermodilution and analysis technique of arterial pulse wave area under curve (AUC) .It helps to better evaluate ,guide and improve treatment in critically ill patients .

3.
Medical Journal of Chinese People's Liberation Army ; (12): 94-98, 2013.
Article in Chinese | WPRIM | ID: wpr-850384

ABSTRACT

Objective To investigate the effects of low ambient temperature on hemodynamics and oxygen dynamics in a porcine hemorrhagic shock model. Methods Thirty-two healthy adult Bama miniature pigs were randomly divided into four groups (8 each): control (group C), shock under room temperature (22°C, group R), shock under low ambient temperature (-10°C, group L) and shock under normal body temperature (keep pulmonary arterial temperature ranged from 38.5 to 39.5°C, group N). The hemorrhagic shock model was reproduced by venous bleeding (40% of total blood volume), and the core temperature (pulmonary arterial temperature and rectal temperature), heart rate (HR), mean arterial pressure (MAP), pulmonary arterial pressure (PAP), pulmonary arterial wedge pressure (PAWP), central venous pressure (CVP), cardiac output (CO), hemoglobin (Hb), saturation of mixed venous blood (SvO2) and blood gas analysis were recorded before reproduction of shock and at different time points after hemorrhagic shock. The whole body oxygen delivery index (DO2I), oxygen uptake index (VO2I), and oxygen extraction ratio (O2ER) were calculated. Results Four pigs died in group N during the experiment, meanwhile, no pig died in other groups. The core temperature in group C, R and L decreased significantly compared with group N (P<0.05), and the core temperature in group L was significantly lower than that in groups C and R from 120 minutes after shock. No difference was found in hemodynamics, oxygen dynamics and prognosis between group R and group L. The HR and VO2I in group N were significantly higher than those in group L and group R, while there was no difference in other indices between the 3 groups. Conclusion The hemodynamics and oxygen dynamics indices don't worsen in hemorrhagic shock pigs under low ambient temperature, possibly resulting from induced hypothermia caused by anesthesia.

4.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 353-355, 2013.
Article in Chinese | WPRIM | ID: wpr-431804

ABSTRACT

Objective To study the effect and safety of dexmedetomidine on the intraoperative fentanyl requirements and cerebral hemodynamics in patients undergoing intracranial tumor surgery.Methods 62 patients scheduled for intracranial tumor surgery were selected and divided into observe group (31 cases) and control group(31 cases).Dexmedetomidine (0.5 μg/kg) was loaded in observe group,and followed by a continuous infusion of a rate of 1.0pμg · kg-1 · h-1 half an hour later.Saline was infused in the same time and the same way in control group.Dose of anesthetic and change of cerebral hemodynamics were recorded and compared.Results The mean heart rate and mean arterial blood pressure were lower in observe group than the underlying value when inducing anesthesia and during the operation (all P < 0.05),while that happened after operation starting 60 minutes later in control group(all P <0.05).The mean heart rate and mean arterial blood pressure were lower in observe group those that in control group (all P < 0.05).Dose of fentanyl and end-tidal sevoflurane concentration were lower in observe group(all P < 0.05).Conclusion Dexmedetomidine used for cerebral hemodynamics stabiliby in intracranial tumor surgery has obvious curative effect and good safety.And it could decrease the dose of anesthetics and anesthesia adjuvant.

5.
Chinese Journal of Ultrasonography ; (12): 851-856, 2013.
Article in Chinese | WPRIM | ID: wpr-442640

ABSTRACT

Objective To evaluate the clinical value of cardiovascular function in patients with type 2 diabetes mellitus by wave intensity and tissue Doppler imaging.Methods According to the course of disease,30 patients with type 2 diabetes mellitus were divided in to two groups:T2DM group 1,the course of disease between 1 year to 5 years; T2DM group 2,the course of disease was longer than 5 years.30healthy volunteers were considered as control group.The parameters of accelerating wave intensity(W1),decelerating wave intensity(W2),negative area(NA),time interval between the R-wave of ECG and the first peak(R-W1),the first and second peaks (W1-W2),elasticity modulus (Ep),stiffness index (β),arterial compliance(AC),pulse wave velocity(PWVβ) and intima media thickness (IMT) were calculated by wave intensity.The left ventricular ejection fraction (LVEF),left ventricular ejection time (LVET),early diastolic peak speed (E),late diastolic peak velocity (A),E / A and isovolumic relaxation time(IVRT) were detected by two dimensional echocardiography.Mitral annular early diastolic peak speeds (Em),late diastolic peak velocity (Am) and Em / Am were detected by tissue Doppler imaging.Then three groups data were recorded and compared.Results Compared with the control group,β,PWVβ,Ep in T2DM group increased significantly(P <0.01 or P <0.05),while AC decreased(P <0.05).IMT in T2DM group 2 was thicker significantly than the control group(P <0.01).PWVβ,Ep,IMT in T2DM group 2 were significantly higher than those of T2DM group 1 (P <0.05).W2 in T2DM group 2 was significantly higher than those of T2DM group 1 and the control group(P <0.01 or P <0.05).E/A,Em and Em/Am in T2DM group were significantly lower than those of the control group (P <0.05 or P <0.01).Compared with T2DM group 1,Em in T2DM group 2 decreased significantly(P <0.05).In T2DM group,there were positive correlation between IMT and Ep,β,PWVβ (r =0.48,r =0.385,r =0.478,P <0.05 or P <0.01),positive correlation between Em and E (r =0.404,P <0.05) ;positive correlation between Em/Am and E/Em,E/A (r =0.602,r =0.559,P <0.01) ; negative correlation between Em and IVRT (r =-0.653,P <0.01);positive correlation between W1 and LVEF (r =0.627,P <0.01); positive correlation between W1-W2 and lVET (r =0.847,P < 0.01) ; no correlation between W2 and E/A,E/Em,Em/Am,IVRT(P >0.05).Conclusions The elasticity of carotid artery and the diastolic function of left ventricular decreased in T2DM patients,while the systolic function of left ventricular was normal.

6.
Chinese Journal of Ultrasonography ; (12): 788-791, 2013.
Article in Chinese | WPRIM | ID: wpr-442614

ABSTRACT

Objective To evaluate the application of liver ultrasound hemodynamic parameters in diagnosing moderate to severe esophageal varices(EV) among patients suffering from portal hypertension.Methods The control group consisted of twenty nine patients without EV.Sixty patients with EV diagnosed by endoscopy were divided into two groups equal in number according to grade of EV.One being mild,the other was moderate to severe.All patients underwent color Doppler flow imaging and contrastenhanced ultrasound,and the dynamic angiography data were collected.Time intensity curves were drawn by software to acquire the arrive time of hepatic artery (HAAT),hepatic vein (HVAT) and portal vein (PVAT).Then HV-HA interval time,PV HA interval time and PV-HV interval time were calculated.The quantitative parameters including HV-HA,PV-HA,PV-HV,damping index (DI) of hepatic vein and portal vein velocity(PVV) were compared.ROC curve was used to assess the value of the parameters above in predicting moderate to severe esophageal varices.Results The difference of PV-HV,PV HA,HV-HA,PVV,DI between the control and the moderate to severe group were statistically significant (P =0.000).PV-HV,PV-HA,HV-HA,DI in moderate to severe group showed statistically significant compared with mild group (P =0.000,P =0.002,P =0.000,P =0.002),however,PVV had no significant (P >0.05) difference between the two groups.Mild group contrasted to the control group,the differences of PV-HA and HV-HA were statistically significant (P =0.000),whereas PV-HV,DI,PVV displayed no significant (P >0.05) difference.The areas under ROC curve of PV-HV,PV-HA,HV-HA,PVV,DI were 0.952,0.775,0.847,0.699,0.808 respectively.The best cutoff value of PV-HV for diagnosing moderate to severe EV was 0.5 second,with sensitivity and specificity of 86.2% and 94.8% respectively.Conclusions The liver ultrasound hemodynamic parameters is helpful in the diagnosis and evaluation of moderate to severe esophageal varices,which is expected to become a new noninvasive method.

7.
Chinese Journal of Ultrasonography ; (12): 496-499, 2013.
Article in Chinese | WPRIM | ID: wpr-434825

ABSTRACT

Objective To investigate the viability of analysis of hemodynamic changes with color Doppler flow imaging in the prediction of acute rejection in transplanted liver.Methods Sixty-eight patients enrolled in the study were categorized into three groups:transplanted liver without acute rejection [rejection activity index(RAI) 0-3,n =24],transplanted liver with mild acute rejection (RAI 4-5,n =23),transplanted liver with moderate and severe acute rejection (RAI 6-9,n =21).All the patients were confirmed by pathology.The color Doppler flow imaging were performed in all the patients within 24 hours and 1 week after biopsy.Results In transplanted liver with moderate and severe acute rejection,the peak systolic velocity of portal vein (PV-PSV) was (31.4 ± 14.1)cm/s,significantly lower than that in transplanted liver without acute rejection,which was (45.1 ± 17.7)cm/s (P <0.05).A week later after steroid therapy,the PV-PSV in transplanted liver with moderate and severe rejection was increased to (46.7 ± 21.8)cm/s(P <0.05).Patients with acute rejection were associated with the decrease of the PVPSV (P <0.05).Conclusions The decrease of PV-PSV may have some clinical value in evaluation the acute rejection in transplanted liver.

8.
Chinese Journal of Ultrasonography ; (12): 406-409, 2013.
Article in Chinese | WPRIM | ID: wpr-434787

ABSTRACT

Objective To investigate if the endothelin-1 (ET-1),nitric oxide(NO) can affect renal artery blood flow and explore the clinical value of ultrasonography in hypertensive disorder complication pregnancy.Methods 18 patients of gestational hypertension,18 patients of gently preeclampsia,20 patients of severe preeclampsia and 20 normal pregnancy women were chosen in random.Color Doppler ultrasonography was used to detect the peak systolic velocity (PSV),end diastolic velocity (EDV),resistive index (RI),pulsatility index (PI) of renal interlobar artery.The levels of serum ET-1 and NO were measured by enzyme-linked immunosorbent assay (ELISA) and nitric acid recovery respectively.Results The level of EDV in preeclampsia patients were significant lower than the control group (P <0.05).The levels of RI,PI,S/D in preeclampsia patients were significant higher than the control group (P <0.05).The level of ET-1 in study group was higher than control group (P <0.01).The level of NO in study group was lower than control group (P <0.01).There was positive correlation between the RI,PI,S/D of renal interlobar artery and the level of serum ET-1.There was inverse correlation between the RI,PI,S/D of renal interlobar artery and the level of serum NO.Conclusions Endothelial dysfunction can cause unbalance of renal vessel systolic-diastolic function.The level of renal artery blood flow parameters can reflect the state of vessel function and have clinical value in hypertensive disorder complication pregnancy.

9.
Chinese Journal of Ultrasonography ; (12): 953-956, 2012.
Article in Chinese | WPRIM | ID: wpr-430007

ABSTRACT

Objective To compare the hemodynamics features of recurrent hepatocellular carcinoma between contrast-enhanced ultrasonography (CEUS) and contrast-enhanced MRI (CEMRI).Methods Forty three recurrent hepatocellular carcinoma lesions in 39 patients were evaluated by CEUS and CEMRI.All lesions were proved by operation or needle biopsy.The dynamic enhancement and washout process on CEUS and CEMRI were analyzed.Results On both two methods,all lesions showed hyperenhancement.Among which,30.2% (13/43) lesions showed hyperenhancement during arterial phase and no washout was found during portal venous phase,37.2 % (16/43) lesions hyperenhanced during arterial phase and washout during portal venous phase.During late phase,the enhancement of 60.5% (26/43) lesions decreased and 7.0% (3/43) lesions showed no washout on CEUS or CEMRI.The overall concordance ratio between two methods was 67.4% (29/43).Difference of hemodynamics features between CEUS and CEMRI was not statistically significant.Conclusions CEUS can accurately display the hemodynamic features of recurrent hepatocellular carcinoma,and enjoy high consistence with CEMRI.

10.
Chinese Journal of Ultrasonography ; (12): 591-594, 2012.
Article in Chinese | WPRIM | ID: wpr-426711

ABSTRACT

Objective To evaluate the significance of color Doppler ultrasound examination of renal blood flow combined with the detection of bone morphogenetic protein-7(BMP-7)in early diagnosis of type 2 diabetic nephropathy.Methods Blood BMP-7 level was tested in 90 patients with type 2 diabetic nephropathy and 30 controls,and parameters of renal blood flow were measured by color Doppler ultrasound examination.Blood BMP-7 level as well as resistant index(RI)of segmental renal artery(SRA)and interlobar renal artery(IRA),were compared between these two groups.Results Compared with controls,blood BMP-7 level gradually decreased with the aggravation of diabetic kidney damage(P<0.01).The peak systolic velocity(Vmax)and the end diastolic velocity(Vmin)of SRA and TRA were slowed gradually,while RI increased(P<0.01).Blood BMP-7 level was negatively correlated with IRA's and SRA's RI of IRA and SRA(r =-0.603,P<0.01;r =-0.652,P<0.01).Conclusions Color Doppler ultrasound examination of renal blood flow combined with detection of BMP-7 might play an important role in early diagnosis of type 2 diabetic nephropathy.

11.
Chinese Journal of Ultrasonography ; (12): 160-163, 2012.
Article in Chinese | WPRIM | ID: wpr-424754

ABSTRACT

Objective To investigate the changes of transcranial Doppler (TCD) patterns and parameters in various intracranial hypertension.Methods Sixty rabbits were randomized into 3 groups:control group,the group of mild-to-moderate intracranial hypertension,the group of serious intracranial hypertension.Acute intracranial hypertension was induced by inflating the balloon inserted into the epidural space.Blood flow velocity was measured with TCD and intracranial pressure (ICP) as well as cerebral perfusion pressure(CPP) was measured.Mannitol was injected to the animals of intracranial hypertension,blood flow velocity and ICP was measured.ResultsTwo characteristic flow patterns vere observed in the group of mild-to-moderate intracranial hypertension:high resistance pattern,systolic flow.At the last stage of extreme intracranial hypertension in the group of serious intracranial hypertension Doppler sonograms showed three characteristic flow patterns in the following sequence:retrograde diastolic flow,very small systolic flow and zero flow.Multiform retrograde diastolic flows were related to the phases of brain death.Very small systolic flow showed three shapes:systolic-spike,small systolic triangular and small double peak.AftermedicinaltreatmentICPdecreasedinthethegroupofmild-to-moderateintracranial hypertension,blood flow velocity also increased.After the same treatment IC,P and blood flow velocity did not change in the group of serious intracranial hypertension.ConclusionsAnalysing patterns and parameters of TCD may be helpful for evaluating ICP indirectly as well as clinical experience.

12.
Chinese Journal of Ultrasonography ; (12): 121-123, 2012.
Article in Chinese | WPRIM | ID: wpr-424715

ABSTRACT

ObjectiveTo explore the characteristics of the fetal pulmonary venous Doppler spectrum in medium-term and terminal pregnancy and to evaluate its application in the cardiac function assessment and lung maturation.Methods The study group consisted of 86 normal fetuses aged from 23rd to 41st week's gestation.The Doppler echocardiography was used to record the pulmonary venous spectra.The peak diastolic velocity (D),deceleration time of D wave,deceleration of D wave (Ddec),the peak systolic velocity (S),acceleration time of S wave,and acceleration of S wave of the right superior pulmonary vein (Sac.c) were measured.Sacc/Ddec was calculated.The Tei index of the left ventricle was calculated.ResultsThe D and deceleration time of D wave and Ddec increased with gestational age (P < 0.05).S,the acceleration time of S wave and Sacc showed no significant correlation with gestational age.Sacc/Ddec ratio was more likely smaller than 1 with the gestational age less than 28 weeks and larger than 1 with the gestational age longer than 28 weeks ( P <0.05).ConclusionsD wave flow velocity,deceleration time of D wave and the Ddec of the right superior pulmonary vein had a good correlation with the global left ventricular function.The Sac/Ddec ratio might be new index for assessing cardiac function and lung maturation.

13.
Chinese Journal of Ultrasonography ; (12): 803-806, 2012.
Article in Chinese | WPRIM | ID: wpr-419366

ABSTRACT

Objective To assess the effects of captopril on renal perfusion of diabetic mellitus(DM)rabbits at early stage by contrast-enhanced ultrasound (CEUS).Methods Of 58 rabbits,6 were control group,37 were made as DM model successfully by alloxan and were randomly divided into 4 groups:untreatment group (n =16) and treatment group A,B and C (n =7 averagely).The treatment groups were given captopril(25 mg/kg weight) everyday by intragastric administration after the DM model established and renal pathology appeared Mogensen DN Ⅰ,Ⅱ or / and Ⅲ respectively.The treatment lasted 12 week.Then CEUS was performed on bilateral kidney to observe the renal perfusion,the parameters included:curve ascending slope(K1),time to peak intensity(PIT),peak signal intensity(PSI),area under the curve(AUC) and time to half of peak intensity(HPT).Results At the end of 12 weeks,compared with control group,PIT and HPT delayed,PSI and K1 decreased in untreatment group and group C,AUC of untreatment group increased.Compared with untreatment group,PIT,HPT and AUC decreased,PSI and K1 increased in group A,B and C.Compared with group C,HPT of treatment group A,B decreased.Compared with control group,renal's size increased and the cortex was thickened in untreatment group and group A,B,C.The pathological examination showed:renal were damaged more seriously in untreatment group than that in group A and B.There was no significant difference in Scr and BUN between all groups.Conclusions Assessment of CEUS for renal perfusion of diabetic mellitus rabbits at early stage is feasible and captopril can improve renal perfusion of DM rabbits.

14.
Chinese Journal of Ultrasonography ; (12): 807-810, 2012.
Article in Chinese | WPRIM | ID: wpr-419363

ABSTRACT

Objective To explore the value of contrast-enhanced ultrasound(CEUS) in the evaluation of the renal cortical perfusion in rabbits in low temperature conditions.Methods 20 New Zealand rabbits were randomly divided into five groups,4 rabbits in each group:1) with the first group as the control group (under the conditions of room temperature) ; 2)The second group was treated under-15℃--23℃ for 8hours; 3)the third group was treated under-15℃--23℃ for 4 hours; 4)the fourth group was treated under-6℃--14℃ for 8 hours; 5) the fifth group was treated under-6℃--14℃ for 4 hours.SonoVue was injected via the ear vein at a dose of 0.1 ml/kg,the renal perfusion imaging was made,observing the dynamic image of 0-3 min after the injection and analyzing the time-intensity curves(TIC)obtained from the following parameters:the slope rate of ascending curve(A),the slope rate of descending curve(α),area under the curve (AUC),time to peak (TTP),and derived peak intensity(DPI).Results Compared with the control group,the A,α of the second and the fourth group were significantly decreased (P < 0.05),while the AUC was significantly increased (P < 0.05) and the TTP was significantly prolonged(P <0.05),for the third and the fifth group,only the A was decreased (P <0.05),and the DPI in each group showed no significant difference.Compared with the third and the fourth group,the AUC of the second group was increased and the TTP was prolonged (P <0.05).Conclusions Contrast-enhanced ultrasound can reflect the earlier renal cortical hemodynamic changes in rabbits in the low-temperature conditions,and is of great value for the early diagnosis of renal damage caused by low temperature.

15.
Chinese Journal of Postgraduates of Medicine ; (36): 11-14, 2012.
Article in Chinese | WPRIM | ID: wpr-419013

ABSTRACT

ObjectiveTo analyze the influencing factors of the blood pressure fluctuation during the perioperative period of pheochromocytoma,and discuss the ways to improve the hemodynamics.Methods The clinical data of patients with pheochromocytoma who had received operation from 2000 to 2010 werestudied retrospectively.The influencing factors of perioperative blood pressure fluctuation were analyzed by statistical methods including Pearson correlation analysis and Logistic regression.ResultsAccording to Pearson correlation analysis,the influencing factors of the highest fluctuation value of the systolic blood pressure ( △ SBP) during the operation included the preoperative highest systolic blood pressure (r =0.196,P =0.013 ),the content of preoperative 24-hour urine epinephrine ( r =0.207,P =0.008 ) and the lost blood volume during the operation (r =0.253,P=0.003).Logistic regression analysis showed that the postoperative persisting hypotension was influenced by the content of preoperative 24-hour urine norepinephrine(OR =1.273,P =0.002) and preoperative preparation duration(OR =0.921,P =0.034);the risk factors of postoperative hypertension were residual tumor (OR =16.920,P =0.001 ) and the preoperative hematocritchange(OR =1.467,P =0.018).ConclusionsIn spite of the adequate preoperative preparation,great changes of blood pressure would still occur during the perioperative period of pheochromocytoma,and it is influenced by many factors.Corresponding measures aiming to these factors should be taken to decrease the perioperative blood pressure fluctuation and surgical risks.

16.
Chinese Journal of Ultrasonography ; (12): 300-304, 2012.
Article in Chinese | WPRIM | ID: wpr-418716

ABSTRACT

Objective To investigate the value of transoral carotid ultrasonography (TOCU) in detecting the change of distal extracranial internal carotid artery(ICA) with stenosis and occlusion in its initial segmen.Methods One hundred and ten patients with stenosis at least 50% or occlusion in the initial segment of ICA diagnosed by high-frequency linear probe were enrolled as case group,while thirty two with healthy carotid arteries as control group.Both of the case and control groups were undergone high-frequency linear probe to examine CCA and the initial segment of ICA,and TOCU to observe their lumen transparency,color Doppler flow display and change of Doppler flow spectrum,even measuring the internal diameter,peak systolic velocity (PSV),end-diastolic velocity(EDV) and PSVICA/PSVCCA ratio,respectively.Digital subtraction angiography (DSA)were performed within two weeks,then compared with ultrasonography.Results 92.7% patients were performed TOCU examination in case group and 93.8% in control group.The internal diameter and PSV of the distal extracranial ICA became gradually smaller from control group to near occlusion group,and there were statistical significance between groups ( P <0.05),however,near occlusion group had no statistical significance compared with occlusion group( P >0.05).There were 80% arteries having thrombus echo in occlusion group,and the others in this group having no thrombus had gloomy colour flow,even got low-velocity artery spectrum.Doppler flow spectrum of distal extracranial ICA showed characteristics of slow wave or single peak in near occlusion group,and spike shape or slow wave in 76.7 % arteries of 70% ~near-occlusion stenosis group,but spike shape in 30.8% arteries of 50%~69% stenosis group,and the others were normal.Conclusions TOCU is useful for detecting the changing regularity of distal extracranial ICA with stenosis or occlusion in its initial segment and has the value of clinical application in association with high-frequency linear probe.

17.
Chinese Journal of Postgraduates of Medicine ; (36): 7-9, 2011.
Article in Chinese | WPRIM | ID: wpr-421208

ABSTRACT

Objective To observe the influence of different dosage of mannitol on hemodynamics after hypertensive intracerebral hemorrhage ( HIH ). Methods Sixty cases with HIH were divided into three groups by random digits table with 20 cases each. Performing routine treatment, also 20% mannitol 250 ml was used 3-4 times/d for 14-21 d in group A,20% mannitol 125 ml was used 2-3 times/d for 3-14 d in group B,and mannitol was not used in group C. The mean blood flow velocity(Vm) and pulsatility index (PI)in bleeding side of the middle cerebral artery (M1) were measured by TCD, and monitoring patient's kidney function. Results After treatment 1 d , Vm comparative differences among three groups were no statistically significant (P > 0.05 ), and after treatment 10 d and 3 weeks, the Vm in group A [(45.01 ± 5.13 ), (59.41 ±7.24) cm/s] and group B [(44.61 ± 5.04), (58.94 ±7.12) cm/s] were significantly higher than those in group C [(42.42 ±4.26), (55.06 ±7.16) cm/s] (P <0.05), but the differences were no statistically significant between group A and group B (P >0.05). With the extension of treatment time, PI recovery gradually, but compared PI,after treatment 1 d, 10 d and 3 weeks,there were no statistical differences among three groups (P > 0.05 ). After treatment 3 weeks, kidney function abnormal ratio in group A [35.0%(7/20)] was significantly higher than that in group B [20.0% (4/20)] and group C [15.0% (3/20)] (P<0.05). Conclusion Using small dosage of mannitol,not only increase HIH cerebral blood flow velocity,improve brain blood perfusion,reduce cerebral ischemic injury,but also reduce kidney damage,safety is higher.

18.
Chinese Journal of Primary Medicine and Pharmacy ; (12): 23-24, 2011.
Article in Chinese | WPRIM | ID: wpr-418202

ABSTRACT

ObjectiveTo observe the influence of Songling Xuemaikang on the hypertension and hemorheology of hyperlipoidemia patients.Methods40 hyperlipoidemia patients randomly divided into Songling Xuemaikang group and jiao gu la zong dai group as a control.The blood lipid and the improvement of hemorheology before and after treatment were compared.ResultsThe efficiency of lipoidemia decrease of treatment and control group is 86.5%and 82.4%,respectively.There was no significant difference between two groups ( P > 0.05 ).The difference of whole blood high shear viscosity,whole blood low shear viscosity,plasma viscosity,whole blood reduced viscosity and fibrinogen between two groups had significant ( P < 0.05 ).ConclusionSongling Xuemaikang had effect on both regulating blood lipid and improving the several indexes of hemorheology.It could be an effective and safe drug for prevention and cure cardiovascular and cerebrovascular disease.

19.
Chinese Journal of Postgraduates of Medicine ; (36): 13-16, 2011.
Article in Chinese | WPRIM | ID: wpr-417330

ABSTRACT

ObjectiveTo investigate the influence of carbon dioxide pneumoperitoneum,posture on blood pressure,heart rate (HR),pulse oxygen saturation (SpO2) of laparoscopic cholecystectomy (LC)and gynecologic surgery (LP) patients.MethodsTwelve LC patients (LC group)and 13 LP patients(LP group) with ASA Ⅰ - Ⅱ were selected.Anesthesia and muscle relaxation were maintained by propofol,fentanyl,enflurane,atracurium and the systolic pressure (SBP),diastolic pressure (DBP),HR,SpO2 was recorded in the following times:before anesthesia(T0),immediately after inflation (T1),after position adjustment (after 10 win inflation ) (T2),after 30 min inflation ( T3 ),after deflation (the end of operation)(T4).Results The SBP and DBP at T1,T2,T3 [SBP:(138.75 ± 13.22),(140.42 ± 15.88),(138.67 ±16.35) mm Hg( 1 mm Hg =0.133 kPa) ; DBP:(94.42 ± 5.76),(96.25 ± 8.26),(90.42 ± 7.36) mm Hg] was higher than that at T0[SBP:( 135.50 ± 15.31 ) mm Hg;DBP:(83.58 ± 6.70) mm Hg] in LC group(P< 0.01 ).The SBP and DBP at T2,T3 [SBP:(136.76 ± 12.55),(136.85 ± 13.22) mm Hg;DBP:(88.38 ±6.54),(87.23 ± 6.34) mm Hg ] was higher than that at T0 [ SBP:( 132.52 ± 10.11 )mm Hg; DBP:(74.61 ± 5.23 )mm Hg] in LP group (P < 0.05 ).There was no significant difference in HR,SpO2 between T0 and the other points in two groups (P > 0.05).ConclusionThe hemodynamic changes have no significant difference between LC and LP;but compared with preoperative,the hemodynamic changes have significant difference after inflation.

20.
Chinese Journal of Ultrasonography ; (12): 578-582, 2011.
Article in Chinese | WPRIM | ID: wpr-416491

ABSTRACT

Objective To study the effects of duration of migration from sea-level to high-altitude on cerebral hemodynamic parameters and their ethnic differences.Methods This randomized comparative study recruited 5 groups of healthy male subjects which were native Hans at sea-level (NHS),Han migrants from sea-level to high-altitude (HMSH,where HMSH-a for residence duration of 4 days,HMSH-b for 1 year,and HMSH-c for 5 years),and native Tibetans at high-altitude (NTH).Color duplex Doppler sonography (CDDS) was used to measure bilateral vertebral and internal carotid arterial diameters,mean flow velocities.The heart rate,arterial blood pressure,and arterial oxygen saturation were also recorded simultaneously,and in combination,hemoglobin was measured to assess total cerebral blood flow (TCBF),total cerebrovascular resistance (TCVR),and total cerebral oxygen supply (TCOS).Results After migration to high-altitude,Hans' TCVR and TCBF maintained the level of NHS after transient changes during early stage (P<0.05),and the TCBF was markedly higher than that of NTH (P<0.05);while the blood pressure and TCOS increased abruptly (P<0.05) at the beginning and kept for a relatively long time at a constant level which were higher than those of NTH all the time (P<0.05).Conclusions Han migrants can acclimate to high-altitude by adaptive change of cerebral blood flow over a short time and maintain a constant adaptability which is always weaker than that of native Tibetans.CDDS can be used for non-invasive measurement of actual cerebral blood flow,and is of good value in the study on high-altitude-related cerebral hemodynamics.

SELECTION OF CITATIONS
SEARCH DETAIL